Hubungan Self Efficacy Pengendalian Cairan dengan Interdialytic Weight Gain di Unit Hemodialisa Rumah Sakit Panti Rapih Yogyakarta

YuliaWardani,, MAN. (2021) Hubungan Self Efficacy Pengendalian Cairan dengan Interdialytic Weight Gain di Unit Hemodialisa Rumah Sakit Panti Rapih Yogyakarta. Caring : Jurnal Keperawatan is an e-journal published by Poltekkes Kemenkes Yogyakarta, 10 (2). pp. 154-165. ISSN 1978-5755

Full text not available from this repository. (Request a copy)

Abstract

The changes of fast-paced and practical lifestyles lead people to unhealthy lifestyles such as consuming instant foods and drinks, lack of activities, and lack of health information. This situation results an increasing numbers of non-communicable diseases, including Chronic Kidney Disease (CKD). Stage 5 CKD requires hemodialysis as renal replacement therapy. One of the problems on hemodialysis patients is an increasing Interdialytic Weight Gain (IDWG) which can cause various complications. Therefore, the IDWG of hemodialysis patients must be controlled by performing fluid control which is highly supported by self-efficacy. The objective of this study is to determine the relationship between fluid control self-efficacy and IDWG at the Hemodialysis Unit, Panti Rapih Hospital, Yogyakarta. This study was conducted by using a cross sectional quantitative method. The total sample of 169 respondents were taken by accidental sampling of 292 patients who underwent hemodialysis. Data analysis was conducted by univariate and bivariate using the Spearman Correlation Test. As the results, the study found that the characteristics of respondents are predominantly based on the age range of 45-64 years (54.4%), male (58.6%), college/ university graduated (46.7%), the length of undergoing hemodialysis was less than 2 years (50.9%), has comorbid (71.6%), has a hypertension’s comorbid (44.1%), IDWG ? 3% or severe (58.6%), high fluid control self-efficacy (98.2%) . Statistically there is no significant relationship between self-efficacy of fluid control and IDWG with a p value of 0.776 (> 0.05). Thus it can be concluded that there is no significant relationship between self-efficacy of fluid control and IDWG. Based on the results of the study, the further research on other factors that influence IDWG such as fluid intake, knowledge and compliance with fluid control in patients undergoing hemodialysis are suggested. Patients who undergo hemodialysis are advised to restrict fluids so that the IDWG value does not exceed the tolerance value, namely ?3%.

Item Type: Article
Subjects: STIKes Panti RApih Yogyakarta > Penelitian Dosen
Divisions: Penelitian Dosen > Yulia Wardani, MAN.
Depositing User: Yulia Wardani, MAN.
Date Deposited: 14 Aug 2022 06:48
Last Modified: 14 Aug 2022 06:48
URI: http://repository.stikespantirapih.ac.id/id/eprint/578

Actions (login required)

View Item View Item